Kohler K-10103 Guia De Instalacion página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
Probable
Causes
L. Hose is
M. The
Low flow.
A. Supply
2.
B. The filters
C. The
3. Constant
A. The
water flow.
B. The
C. The
1056542-2-B
Recommended Action
L. Check the hoses to make
kinked.
certain they are not kinked. If
a hose is kinked, disconnect the
hose, straighten, then reconnect.
M. Remove the valve cover and
solenoid
solenoid. Replace the solenoid
as needed. Refer to the "Test
does not
work.
and Service the Solenoid"
section of the Homeowners
Guide.
A. Check filtration systems for
pressure is
blockage. Check incoming
low.
water pressure. Pressure should
be at least 20 psi (137 kPa).
B. Refer to the "Service the Filters"
are
section of the Homeowners
plugged.
Guide.
C. Remove the aerator and clean.
aerator is
For calcium/mineral deposits,
plugged.
soak the plastic insert in a 50:50
mix of water and vinegar. Soak
only the plastic insert.
A. Turn off the water supply and
diaphragm
purge the faucet. Remove the
seal is
cover and check the diaphragm
dirty or
and surrounding area for
damaged.
debris. Clean out any debris. If
the diaphragm is damaged,
order a replacement. Refer to
the "Service the Diaphragm"
section of the Homeowners
Guide.
B. Remove the valve cover and
battery life
replace the battery. The spout
has
requires a standard 2CR5 6 V
expired.
lithium battery. This item is not
available from Kohler Co., but
can be purchased at retail
stores.
C. Remove the valve cover and
solenoid is
solenoid. Check the solenoid
plugged.
holes for debris.
12
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-10104