Troubleshooting (cont.)
Symptoms
Probable
Causes
D. The
E. The filters
4.
Sporadic
A. The wires
water flow.
B. The
5.
Sensor
A. The
flashes once
approximately
every 8
seconds. The
product
continues to
operate.
6. Sensor
A. The
flashes once
approximately
every 2
seconds. The
product does
not operate.
Kohler Co.
Recommended Action
D. Remove the valve cover and
solenoid
solenoid. Replace the solenoid
as needed. Refer to the "Test
does not
work.
and Service the Solenoid"
section of the Homeowners
Guide.
E. Refer to the "Service the Filters"
are
section of the Homeowners
plugged.
Guide.
A. Remove the cover and inspect
are
the wires/cables for cuts or
pinched or
damage. If the wires are cut or
damaged.
damaged, order a new
solenoid, sensor assembly,
sensor extension cable, or
battery holder. Do not pinch or
damage the wires during
reassembly.
B. Remove the valve cover and
battery life
replace the battery. The spout
has
requires a standard 2CR5 6 V
expired.
lithium battery. This item is not
available from Kohler Co., but
can be purchased at retail
stores.
A. Replace the battery. The
battery
product may continue to
power is
operate for several days with
low.
low battery power. The product
requires a 2CR5 6 V lithium
battery. This item is not
available from Kohler Co. but
can be purchased at a local
retail store.
A. Replace the battery. The
battery
product requires a 2CR5 6 V
power is
lithium battery. This item is not
insufficient
available from Kohler Co. but
to allow
can be purchased at a local
the
retail store.
product to
operate.