Kohler K-4386 Guia De Instalacion página 5

Ocultar thumbs Ver también para K-4386:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

* Refer to gasket
instructions
Gasket
3. Install the Bowl
CAUTION: Risk of personal injury or product damage.
Overtightening the T-bolts may cause breakage or chipping of the
vitreous china.
Install the gasket to the bowl. Refer to the gasket installation
instructions supplied by the manufacturer.
NOTE: For a floor-mounted wall-outlet bowl, an all-wax ring is not
recommended.
Carefully align and set the bowl into position.
Tighten the T-bolts.
Ensure that the gasket is properly sealed.
Install the 1/4" (6 mm) floor bolts.
Assemble the bolt cap bases, washers, and nuts to the floor bolts.
Tighten the nuts. Do not overtighten.
NOTE: If the floor bolts extend more than 1/4" (6 mm) from the top
of the nut, loosen the nut and turn the bolt further into the floor.
Retighten the nuts.
Place the bolt caps over each floor bolt.
Kohler Co.
Bolt Caps
Nut
Washer
Bolt Cap Base
1/4" Floor Bolts
5
1007283-2-B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-4388K-4396K-43984396-0

Tabla de contenido