2.2 Pre Operation
First, make sure the equipment is stable in its position. Before using the equipment, the
parts that will be in contact with the product that will be processed shall be washed with
water and soap (see item 3.3 Cleaning and Sanitizing).
2.2.1 Disassembling the Plates
Step 1: Open the Lid fastenings (#01 Pic.05) and tilt the Chamber Lid (#02 Pic.05);
Before opening the Chamber Lid #02 (Pic. 05), make sure the Plate #03 (Pic. 05) is
Steel Gloves should be used to handle the Plates, since the knife edges are sharp
Step 2: Carefully remove the Plate #03 (Pic. 5), turning it anticlockwise and pulling it up;
Step 3: Remove the Expeller Dish #04 (Pic. 05), lifting it up.
2.2.2 Assembling the Plates
Step 1: Place the Expeller Dish #04 (Pic. 05);
Step 2: Carefully place the Plate #03 (Pic. 05) chosen for the operation;
Step 3: Close the Chamber Lid #02 (Pic. 05);
Step 4: Lock the Lid Fastenings #01 (Pic. 05) to fix the Chamber Lid in the right position.
PICTURE 04
IMPORTANT
stopped.
IMPORTANT
and may wound the operator.