Control Panel
K-1569/1669 Steam Hardware Locations
21" (53.3 cm)
Steam
Head
6"
(15.2 cm)
K-1681/1683 Steam Hardware Locations
Locate the steam control inside the shower module on the same wall as the shower controls.
Locate the steam head on the opposite wall. All measurements are from the inside of the module.
For custom shower applications: Install the steam head
6" (15.2 cm) above the floor and away from any sitting area.
3. Recommended Layout Options
1045789-2-C
12" (30.5 cm)
60"
(152.4 cm)
4-1/2"
(11.4 cm)
Steam Head
Control
Panel
60"
(152.4 cm)
Drain End
6" (15.2 cm)
Steam Head
K-1687/1688 Steam Hardware Locations
Steam
Head
K-1682/1684 Steam Hardware Locations
Threshold
Custom Shower Applications
8
Control
Panel
60"
(152.4 cm)
6" (15.2 cm)
21" (53.3 cm)
Control
Panel
60"
(152.4 cm)
Drain End
4-1/2"
(11.4 cm)
Min
6" (15.2 cm)
from floor
21" (53.3 cm)
11"
(27.9 cm)
Steam
Head
Steam
Head
6"
(15.2 cm)