5. Install the Main Unit
WARNING: Risk of fire. There should be a minimum of 12" (30.5 cm) of air space around the steam
generator at all times. This provides an area for the heat generated by the unit to dissipate.
WARNING: Risk of personal injury. Do not plumb a trap or pressure relief valve into the steam line.
Plumbing the pressure relief valve into the steam line can be hazardous if the steam outlet is capped.
Install the desired drain/spill pan under the unit.
We recommend that the pressure relief valve be connected to a drain line. The drain line should
meet all applicable codes.
Attach the water supply line to the water inlet.
1045789-2-C
Maintain a 12" (30.5 cm)
space around the unit.
RJ-12
Drain/Spill Pan
Steam Outlet
Pressure
Relief Valve
Inlet
Drain (install
per applicable
codes)