Operation

Stop Routine

WARNING
NEVER insert hands or objects into basket
until it has completely stopped. Doing so
could result in serious injury.
A lengthy stop procedure ensures that the
basket has adequate time to stop (from the
machine's highest speed) before the computer
allows the door to be opened. This is an
important safety feature.
During the normal stop routine at the end of
the cycle, the computer will display "STOP"
and turn off all outputs.
A 30-second shakeout (Wash 1) is included as
part of the stop procedure. If additional
shakeout is desired, see Programming a Spin
Step in the Programming section of this
manual.
The remainder of the stop routine is fixed at
the following:
• low speed forward for 15 seconds
• pause for 5 seconds.
The computer will display "DONE," and the
door can be unlocked. The computer will
continue to display "DONE" until the operator
opens the door. Once the door is opened, the
display will change to "NEXT."

Balance Switch Detection

The washer-extractor is equipped with a
balance switch detection system whereby the
switch installed between the faces of the
22
A-frame signals the computer to slow the
washer-extractor when an out-of-balance load
occurs during extract.
If the balance switch is tripped, the out-of-
balance LED indicator located in the upper left
corner of the first digit of the display will light
and will remain lighted until the end of the
SW012
extract step. This indicator tells the operator
that an out-of-balance condition existed during
an extract step. The washer-extractor will
attempt to balance three times during an
extract step.
If on the third attempt the out-of-balance
condition continues, the washer-extractor will
advance to the next step. (If the next step is
another spin step, it will be skipped also.)
Note: This feature applies to the UW60 only.
Note: The computer cannot advance through a
drain step.

Temperature Display

The temperature display can be prompted to
display in Fahrenheit or Centigrade. See
Prompting the WE-6 in the Programming
section of this manual.
To display temperature, press the Display
Temp key. The display will read "F" or "C"
and the temperature as long as the key is
pressed. The computer will update the display
automatically.