3
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
2
1
5
6
Adjust temperature limit stop! Turn on water
supplies; let the water run at both full hot and
full cold to ensure the water is running as hot/
cold as possible. Place a thermometer in a
plastic tumbler, and hold the tumbler in the
water stream. Place the temperature knob (1)
onto the splines (2), then rotate the temperature
knob counter-clockwise until you achieve your
maximum desired temperature from the outlet
(not more than 120° or the lower temperature
mandated by your local plumbing code).
If max temperature is not achieved before limit
stop (3) on temperature knob (1) meets the limit
stop (4) on the volume control handle. Remove
the temperature control knob (1) from splines (2).
Rotate temperature control knob (1) clockwise.
Place temperature control knob (1) back onto
4
Siderna
®
10
13
12
11
7
60 Series Installation
14
splines (2) and continue to rotate counter-
clockwise until maximum desired temperature is
achieved.Remove the temperature knob (1) and
replace onto the splines (2), making sure that the
temperature knob limit stop (3) hits against the
volume handle limit stop (4) as shown. Secure
the temperature knob using screw (5) and place
cap (6) on knob.
For Siderna
(series T60X80) models, place
®
temperature handle (knob) (10) onto valve stem
and secure with screw (11). Ensure O-ring (12) is
assembled on handle cap (13). Install handle cap
by pressing it into place on top of the temperature
handle (10). Secure cap by tightening screw (14)
from the underside of the handle.
4