ENGLISH
ENGLISH
Make sure that the outlet is near the product
to install. So, if the cable that came with the
product is not long enough, you will need to
replace it with another one having the same
features but with the right length.
Adjustment to different type of gas
WARNING
-
This operation must be performed by a
If the appliance is intended to operate with
a different gas from the gas type stated on
the rating plate and information label on
the top of the hob, change the injectors.
Remove the information label and keep it
with the instructions booklet.
Use pressure regulators suitable for the gas
pressure indicated in the Instruction.
-
The gas nozzles must be changed
technician.
-
Nozzles not supplied with the appliance
must be ordered from After Sales
Service.
-
Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used
(G30/G31), the minimum gas setting screw
must be tightened as far as it will go.
IMPORTANT: should you experience
please contact the After Sales Service for
the replacement of the burner tap if found to
be faulty.
Replacing the injectors (see paragraph
"injector table")
-
Remove grids (A).
-
Extract burners (B).
-
Using a socket spanner of the
appropriate size unscrew the injector
(C), unscrew the injector to be replaced.
-
Replace it with the injector suitable for
the new type of gas.
-
Re-assemble the injector in (D).
the gas calibration plate supplied with
the injectors in such a way that it covers
the existing information relating to gas
calibration.
D
C
Adjusting minimum gas setting of taps
To ensure that the minimum setting is
correctly adjusted, remove the knob (E) and
proceed as follows:
-
(-);
14
18
A
B
E