Injector Table - IKEA ELDSLÅGA Manual De Instrucciones

Ocultar thumbs Ver también para ELDSLÅGA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E
ENGLISH
N
G
L
S I
H

Injector table

Injector table
Category II2H3+
Type of gas used
NATURAL GAS
(Methane)
G20
LIQUEFIED
PETROLEUM GAS
(Butane) G30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Type of gas
used
G20 20 mbar
G30
28-30 mbar
G31
37 mbar
Electric Power: 220 - 240 V ~ 50 - 60 Hz 0,6 W
Type of
Injector
burner
marking
power burner
146 A
rapid
115 Y
semi-rapid
101 Z
auxiliary
72 X
power burner
93
rapid
85
semi-rapid
69
auxiliary
50
power burner
93
rapid
85
semi-rapid
69
auxiliary
50
Model
Rated thermal
5 BURNERS
1 PB - 1 R
2 SR - 1 AUX
1 PB - 1 R
2 SR - 1 AUX
1 PB - 1 R
2 SR - 1 AUX
Rated
Rated
thermal
consumption
kW
4.00
381 l/h
3.00
286 l/h
2.00
190 l/h
1.00
95 l/h
3.70
269 g/h
3.00
218 g/h
2.00
145 g/h
1.00
73 g/h
3.70
264 g/h
3.00
214 g/h
2.00
143 g/h
1.00
71 g/h
Total rated
consumption
12.00
11.70
11.70
Reduced
Gas pressure
heat
(mbar)
capacity
min. rat. max.
kW
2.20
0.60
17
0.35
0.30
1.90
0.70
20 28-30 35
0.40
0.35
1.90
0.70
25
0.40
0.35
Air required (m
for burning1m
gas
1142 l/h
851 g/h
836 g/h
15
1 1
20
25
37
45
)
3
of
3
9.52
30.94
23.80

Publicidad