Battery Selection - Zoeller ProPak 508/53 Instrucciones De Instalación

Sistema pre-ensamblado de bomba de sumidero con batería de reserva
Ocultar thumbs Ver también para ProPak 508/53:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Manufacturer warrants, to the purchaser and subsequent owner
during the warranty period, every new product to be free from defects
in material and workmanship under normal use and service, when
properly used and maintained, for a period of three years from date of
purchase by the end user. Parts that fail within the warranty period,
that inspections determine to be defective in material or workmanship,
will be repaired, replaced or remanufactured at Manufacturer's option,
provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No
allowance will be made for shipping charges, damages, labor or other
charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval of
Manufacturer, subjected to misuse, misapplication, neglect, alteration,
accident or act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions;
that has been exposed to outside substances including but not limited
to the following: sand, gravel, cement, mud, tar, hydrocarbons,
hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive
or corrosive substances, wash towels or feminine sanitary products,
In those instances where damages are incurred as a result of an alleged pump failure, the homeowner must retain possession
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure.
The DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user.
The system is designed for installation in sumps with minimum of 18" (45.7 cm) diameter and 24" (61 cm) deep. For 18" x 22" (47.5 cm x 55.9
cm) applications, consult factory.
The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. A
deep-cycle, 12 volt, 105 amp-hour marine battery or larger is recommended and will provide approximately 6 hours of continuous pumping
time in a sump pump installation with 8' (2.4 m) of head pressure. In most installations the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended for ease of installation. These batteries contain acid and proper
precaution must be taken when handling. Maximum battery size to fit inside battery box is 12-1/2" (31.8 cm) Length x 7" (17.8 cm) Width x
9-1/2" (24.1 cm) Height.
There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never
become fully charged and may damage the charging circuits of the control. It is for this reason that Zoeller offers its own line of batteries.
We offer both a Water/Acid Deep-Cycle Battery which can run the pump continuously for over 6 hours, and a Maintenance-Free AGM
Battery, which will power the pump for over 5-1/2 hours. These times are based on continuous pumping at 8' (2.4 m) of static head. Actual
times will vary depending on static head, volume of water entering the pit, and the condition of the battery.
Follow these recommendations:
• Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity or larger
• Do NOT use a "maintenance-free" battery unless it is an AGM battery
• Replace your battery every 3 years
• Do not let corrosion build up on the battery terminals
• To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)
• Use of included plastic battery box is recommended to keep battery safe and clean
PROTECT YOUR WARRANTY:
• Water level in batteries must be checked once a month (wet cell batteries only)
LIMITED WARRANTY
etc. in all pumping applications. The warranty set out in the paragraph
above is in lieu of all other warranties expressed or implied; and we do
not authorize any representative or other person to assume for us any
other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention: Product Support Department to obtain any needed repair or
replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE
DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
of the pump for investigation purposes.
DESCRIPTION

BATTERY SELECTION

THE AQUANOT
BATTERY
®
© Copyright 2020 Zoeller
Co. All rights reserved.
®
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Propak 508/98

Tabla de contenido