NOTICE TO INSTALLER: Instructions must remain with installation.
Your Peace of Mind is Our Top Priority
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP
Patent No. D740329
1. Make certain that the receptacle is within reach of the pump's power supply cord.
Do not use primary pump circuit. DO NOT USE AN EXTENSION CORD. Extension
cords that are too long or too light do not deliver sufficient voltage to the pump motor,
and they could present a safety hazard if the insulation were to become damaged
or the connection end were to fall into a wet or damp area.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to
the National Electrical Code for the current shown on the pump nameplate.
3. Testing for ground: as a safety measure, each electrical outlet should be checked for
ground using an Underwriters Laboratory Listed circuit analyzer which will indicate
if the power, neutral and ground wires are correctly connected to your outlet. If they
are not, call a qualified, licensed electrician.
4. For Added Safety: pumping and other equipment with a 3-prong grounded plug must
be connected to a 3-prong grounded receptacle. For added safety the receptacle
may be protected with a ground-fault circuit interrupter. When a pump needs to be
connected in a watertight junction box, the plug can be removed and spliced to the
supply cable with proper grounding. For added safety this circuit may be protected
by a ground-fault circuit interrupter. The complete installation must comply with the
National Electrical Code and all applicable local codes and ordinances.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong
grounded plug to help protect you against the possibility of electrical shock. DO
NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. The 3-prong
plug must be inserted into a mating 3-prong grounded receptacle. If the installation
does not have such a receptacle, it must be changed to the proper type, wired and
grounded in accordance with the National Electrical Code and all applicable local
codes and ordinances.
6. The tank is to be vented in accordance with local plumbing code. Pumps must be
installed in accordance with the National Electrical Code and all applicable local codes
and ordinances. Pumps are not to be installed in locations classified as hazardous
in accordance with National Electrical Code, ANSI/NFPA 70.
7 .
Risk of electrical shock. Do not remove power supply cord and strain relief
or connect conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should be performed by
a qualified, licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electrical shock. These pumps have not been investigated for use in swimming
pools and marine areas.
11. According to the state of California (Prop 65), this product contains chemicals known
to the state of California to cause cancer and birth defects or other reproductive harm.
12. It is the owner's responsibility to check the battery and battery connection at least
once a month. Batteries contain acid and caution must be taken when handling.
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
MODEL 508 - 12 V DC BATTERY BACKUP SYSTEM
WITH 115 V AC POWERED SUMP PUMP
MODEL M53 OR M98
INSTALLATION INSTRUCTIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2016 Zoeller
508/53
508/98
CAUTION
1. Check to be sure your power source is capable of handling the voltage requirements
of the motor, as indicated on the pump name plate.
2. Vent hole. It is necessary that all submersible sump, effluent, and sewage pumps
capable of handling various sizes of solid waste be of the bottom intake design
to reduce clogging and seal failures. Vent holes should be checked periodically
for clogging. The 50 Series pumps have a vent located in the pump housing
opposite the float, adjacent to a housing lug. Water stream will be visible from
this hole during pump run periods.
3. Pump should be checked frequently for debris and/or build up which may interfere
with the float "on" or "off" position. Repair and service should be performed by an
Authorized Service and Warranty Center only.
4. Dewatering and effluent sump pumps are not designed for use in pits handling
raw sewage.
5. Maximum operating temperature must not exceed 130 °F (54 °C).
6. Do not operate a pump in an application where the Total Dynamic Head is less
than the minimum Total Dynamic Head listed on the Pump Performance Curves.
7. For indoor use only.
8. DC emergency pumps are designed for handling clear water. Do not use in septic
tanks to pump effluent or sewage pits to pump sewage.
9. Repair and service of your DC backup system should be performed by an
Authorized Service and Warranty Center.
10. The installation of DC automatic backup pumps requires the use of a variable level
float switch for operation. It is the responsibility of the installing party, to ensure
that the float switch will not hang up on the pump apparatus or pit peculiarities
and is secured so the pump will turn "on" and "off". It is recommended that the pit
be 18" (45.7 cm) in diameter or larger to accommodate both a primary and a DC
backup pump.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL Standard UL778.
CSA Certified pumps are certified to CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
visit our web site:
www.zoellerpumps.com
NOTICE: VENT HOLE FOR
CHECK VALVE SEE #2 IN
CAUTION SECTION BELOW
DATE INSTALLED:
MODEL NUMBER:
SEE BELOW FOR
LIST OF CAUTIONS
FM2834
1116
Supersedes
1016

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zoeller ProPak 508/53

  • Página 1 12. It is the owner’s responsibility to check the battery and battery connection at least CSA Certified pumps are certified to CSA Standard C22.2 No. 108. once a month. Batteries contain acid and caution must be taken when handling. REFER TO WARRANTY ON PAGE 2. © Copyright 2016 Zoeller Co. All rights reserved. ®...
  • Página 2: Battery Selection

    There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged and may damage the charging circuits of the control. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/ Acid Deep-Cycle Battery which can run the pump continuously for over 6 hours, and a Maintenance-Free AGM Battery, which will power the pump for over 5-1/2 hours.
  • Página 3 10. Vent gases and odors to the atmosphere through vent pipe. 3. Securely tape or clamp power cord to discharge pipe, clear of the float 11. Install Zoeller Pump Stand (Model 10-2421) under pump to mechanism(s). provide a settling basin.
  • Página 4 © Copyright 2016 Zoeller Co. All rights reserved. ®...
  • Página 5 3' (1 m) or 4' (1.2 m) above the sump. 24 V AC/DC and 0.5 amps. It can be used with an auto-dialer (such as the Zoeller 10-2616), alarm or home security system. Read the auxiliary 6. Connect the green sensor wire to the sensor connector (Figure 3).
  • Página 6 1-1/2" PVC pipe tee 005645 153766 153766 1-1/2" X 2-1/8" long pipe 150197 1-1/2" X 8-3/4" long pipe / sch 40 010619 019509 019509 Fuse, 30 Amp AGC 012353 012353 012353 © Copyright 2016 Zoeller Co. All rights reserved. ®...
  • Página 7: Troubleshooting Information

    If the above checklist does not uncover the problem, consult the factory - do not attempt to service or otherwise disassemble pump. Service must be performed by Zoeller Authorized Service Centers. Go to www.zoellerpumps.com/service stations to find the Authorized Service Centers in your area.
  • Página 8 Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false activa- tion, Zoeller Company recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior. Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector.
  • Página 9 Laboratory, lo cual indicará si los cables de alimentación, neutro y de tierra están únicamente por una estación de servicios autorizada por Zoeller Pump Company. conectados correctamente a la toma de corriente. Si no lo están, llame a un electricista 4.
  • Página 10: Garantía Limitada

    Cada año se fabrican millones de baterías, por lo que es imposible garantizar una calidad constante. Una batería defectuosa nunca llegará a cargarse completamente y puede dañar los circuitos de carga del control. Es por ello que Zoeller ofrece su propia línea de baterías. Ofrecemos baterías de agua/de ácido de ciclo profundo que pueden accionar la bomba de forma continua durante más de 6 horas y una batería AGM libre de mantenimiento...
  • Página 11: Instalación Recomendada Para Todas Las Aplicaciones

    5. El contenedor para agua debe ser de conformidad con los códigos y ventilación. especificaciones pertinentes. 11. Instale el soporte de la bomba Zoeller (modelo 10-2421) debajo de la bomba para proporcionar un contenedor para el agua de sedimentación. RENDIMIENTO Rendimiento de la bomba de CC con batería de 12 V completamente cargada...
  • Página 12 © Copyright 2016 Zoeller Co. Todos los derechos reservados. ®...
  • Página 13: Arranque Inicial Y Funcionamiento

    (como el Zoeller 10-2616), cerca. El cargador de control debe estar situado a 0.9 o 1.2 m (3 o 4 pies) alarma o sistema doméstico de seguridad.
  • Página 14: Lista De Verificación

    Tubo largo DN40 x 5.5 cm (1-1/2 pulg. x 2-1/8 pulg.) 150197 Tubo largo DN40 x 5.5 cm (1-1/2 pulg. x 8-3/4 pulg.) / sch 40 010619 019509 019509 Fusible, 30 A AGC 012353 012353 012353 © Copyright 2016 Zoeller Co. Todos los derechos reservados. ®...
  • Página 15: Información De Solución De Problemas

    Si la lista de verificación arriba mencionada no revela el problema, consulte con el departamento de Product Support. No intente proporcionar algún servicio o desarmar la bomba. Las estaciones de servicio autorizadas por Zoeller deberán proporcionar dicho servicio. © Copyright 2016 Zoeller Co.
  • Página 16: Interruptor Del Flotador

    Algunos de estos subproductos pueden producir un olor a huevo podrido. Además, algunos de estos subproductos pueden provocar que un detector de monóxido de carbono se active falsamente. Con el fin de ayudar a evitar una activación falsa, Zoeller Company recomienda poner la batería lo más alejada posible del detector de CO o, si es necesario, ventilar la batería hacia el exterior.
  • Página 17 être effectués uniquement par un centre d'entretien autorisé si l'alimentation, le neutre et la terre sont reliés correctement à votre prise. S'ils ne le de Zoeller Pump Company. sont pas, il faut faire appel à un électricien professionnel et qualifié.
  • Página 18: Garantie Limitée

    Chaque année, des millions de batteries sont fabriquées et il est donc impossible de garantir une qualité constante. Une batterie défectueuse ne va jamais charger entièrement et peut endommager les circuits de chargement de la commande. C’est pour cette raison que Zoeller propose sa propre gamme de batteries.
  • Página 19 10. Un tuyau d'évent doit ventiler les gaz et les odeurs vers l'atmosphère. 4. Utiliser un tuyau d’évacuation de pleine grandeur. 11. Installer le pied de pompe Zoeller (modèle 10-2421) sous la pompe pour 5. La cuve doit être conforme aux codes et à la réglementation en vigueur.
  • Página 20 © Copyright 2016 Zoeller Co. Tous droits réservés. ®...
  • Página 21 24 V c.a./c.c. et de 0,5 A. Elle situé entre 0,9 et 1,2 m (3 et 4 pi) au-dessus du puisard. peut être utilisée avec un numérateur automatique (tel le Zoeller 10-2616), 6. Raccordez le fil vert du capteur au raccordement du capteur (figure 3).
  • Página 22: Liste De Vérification

    Tuyau long, 3,8 cm (1-1/2 po) x 5,4 cm (2-1/8 po) 150197 S.O. S.O. Tuyau long, sch 40, 3,8 cm (1-1/2 po) x 22,2 cm (8-3/4 po) 010619 019509 019509 Fusible, 30 A AGC 012353 012353 012353 © Copyright 2016 Zoeller Co. Tous droits réservés. ®...
  • Página 23 Ne serrez pas trop les raccords ni les vis. Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les réparations doivent être faites par un centre de réparation agréé par Zoeller. © Copyright 2016 Zoeller Co.
  • Página 24 Certains de ces sous-produits peuvent produire une odeur d’œuf pourri. Certains de ces sous-produits peuvent également engendrer l’activation erronée d’un détecteur de CO. Afin d’éviter toute activation erronée du détecteur de CO, Zoeller Company recommande de déplacer la batterie aussi loin que possible du détecteur, ou si nécessaire, de ventiler la batterie vers l’extérieur.