Descargar Imprimir esta página

Electrical Information - Dornbracht eUnit Shower Manual Del Usuario

Ocultar thumbs Ver también para eUnit Shower:

Publicidad

Electrical information

Electrical installation
Only connect to the electricity supply when the device is voltage-free.
Inexpertly completed electrical installations and electrical installations that are not completed as stipulated in this guide can cause
!
electric shocks which could result in serious injury or even death, as well as damage to property.
The electrical installation must be implemented in accordance with IEC 60364-4-41 and DIN VDE 0100 by a qualified electrician.
Please conform to national statutory regulations, where different.
Combine the devices only with original Dornbracht components.
Equipotential bonding
Do not create equipotential bonding over water pipes.
!
It is essential to use and/or install equipotential bonding cables (4 mm² / AWG 11).
Provided by customer:
– Fuse box in accordance with planning requirements
– Safety cut-out (6 A, type B)
– Earth-leakage circuit breaker (30 mA, 2-pin, type A),
– 1 x circuit-breaker switch (16 A)
– 2 x DIN rail mounting TS 35
– Equipotential bonding strip
– Network connection in accordance with TIA 568A, if necessary
5

Publicidad

loading