Dip-Switches
DIP1
DIP2
DIP3
DIP4
DIP5
DIP6
With all DIPs on ON, the control unit switches to SERVICE MAN mode.
The SWO and SWC inputs are deactivated.
The OPEN/CLOSE push-buttons must be kept pressed during operation. The opening of the STOP
input stops the motor.
When DIP1 is moved to ON, the board indicates that the torque has been applied during a number of
flashes (from 1 to 4) of the DL2 green LED, followed by a 3-s interval.
The max torque is indicated with DL2 green LED with fixed light.
To increase the torque, press P1. The DL2 LED changes the number of flashes to indicate the selected
torque value.
Once the desired torque is selected, move DIP 1 to OFF to memorise this presetting.
Note: with actuators for rolling shutters, preset torque at the maximum value.
The radio receiver in this product is compatible with the new ARC (Advanced Rolling Code) transmitters
which, thanks to 128-bit encryption ensure superior copy-security.
Storing new ARC transmitters is quite similar to that of normal rolling code transmitters with HCS cod-
ing, but be aware that:
1) ARC transmitters and Rolling Code HCS can not be stored in a single receiver.
2) The first transmitter memorized determines the type of transmitters to be used later. If the first
transmitter memorized is ARC, you can not store Rolling code HCS transmitters, and vice versa.
3) Fixed code transmitters may only be used in conjunction with Rolling code HCS transmitters, bring-
ing the logic CVAR OFF. They are, therefore, not usable in combination with the ARC transmitters.
If the first rolling code transmitter stored is an ARC CVAR the logic is inoperative.
4) If you want to change the type of transmitters it is necessary to proceed with a receiver reset.
10
DIP-SWITCH FUNCTION
Function
Description
To be used for the programming of the torque, as shown
TORQUE
hereunder. After presetting the parameters, move to OFF again.
The automatic closure is enabled or disabled.
TCA
Off: disabled automatic closure.
On: enabled automatic closure.
The operating mode of input DAS/PHOT is selected:
DAS/PHOT
Off: partial reversion (3s) at activation of safety edge.
On: total reversion at activation of edge/photocell.
Off: during closure, if SWC is pressed, the motor is blocked.
On: during closure, if SWC is pressed, the motor continues its
SWC MODE
closing movement for further 2 seconds or until the SAFETY
EDGE is activated.
Select how OPEN input (13) works:
ON: during opening an OPEN command is ignored
BLI
During closing an OPEN command reverse the motion.
OFF: Works according DIP 6 setting
The operating mode of input 13 (Open) is selected.
Available only with DIP 5 OFF
OPEN/PP
On: PP Operation: OPEN > STOP > CLOSE > STOP>.
Off: OPEN operation always.
ADJUSTMENT OF THE TORQUE (DIP1:ON)
RADIO SELF-LEARNING (DIP1:OFF/DIP6:ON)
SERVICE MAN MODE