Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
Use:
Two systems are available
Exhaust mode (S)
Vapours are extracted outside through an
exhausting pipe that is affixed to the connection
ring above the hood.
Diameter of the exhausting pipe must be equal to
that of the connection ring.
In the horizontal runs the duct must be slightly
slanted (about 10°) and directed upwards to vent
the air easily from the room to the outside.
Attention!
If the hood is supplied with carbon filter,
then it must be removed.
Filter version (K)
The air is filtered through a carbon filter (for its
installation see paragraph "Carbon filter") and
recirculated into the room through the grating on
the lower side of the chimney.
Attention!
If the hood is not supplied with carbon filter,
then it must be ordered and mounted.
This version is used when there is no exhaust
duct for venting outdoors or when it is impossible
to install one.
Installation
When installed, the distance between hood and
burners must be not less than 65 cm. above
electric burners or 75 cm. above gas or mixed-
fuel burners.
Electric connection
Before completing any connection, make sure the
house voltage corresponds with the voltage
indicated on the label affixed inside the hood
It is advisable to call a qualified technician to make
the electrical connection.
Appliance fitted with plug.
Connect it to a socket which conforms with
current regulations.
If you intend to connect it directly to the electric
mains, remove the plug and fit an approved
bipolar switch with a minimum contact opening of
no less than 3mm.
If the plug is not accessible once it has been
inserted in the socket, it will however be
necessary to fit an approved bipolar switch with
a minimum contact opening of no less than 3mm.
GB
Appliance without plug
Fit an approved plug or an approved bipolar
switch with a minimum contact opening of not
less than 3mm.
The manufacturers are not liable for any problems
caused by the user's failure to observer the
above instructions.
Fastening of shelves (optional)
Fasten the four side supports I to the adjacent
cabinets and place the shelf on the supports
(Fig. 4).

Using the hood

— The hood is provided with a motor with several
speeds. For the best performance, we
recommend using the low speeds in normal
conditions and the high speeds in particular
cases of strong odour and vapour
concentration.
— We recommend starting up the hood a few
minutes before cooking and keeping it running
until all the odours have been eliminated.
Electronic control panel
2 3 4
1
1- Motor OFF button
2- On button and motor speed selection button 1
- 2 - 3 - 1 - 2 - . . . .
3- Speed 1 LED
4- Speed 2 LED and metal grease filter saturation
LED (in this latter case, the LED will flash - See
instructions on grease filter cleaning).
5- Speed 3 LED and carbon filter saturation LED
(in this latter case, the LED will flash - See
instructions on active carbon filter
replacement).
Warning!
The active carbon filter saturation LED is not
activated.
In order to activate the carbon filter saturation
indicator, press buttons 2 and 7 simultaneously
for 3 seconds. Initially, only LED 4 will flash, then
after the 3 seconds have passed, LED 5 will also
start flashing, indicating that the carbon filter
saturation control system is active.
13
5 6 7
8
9

Publicidad

Tabla de contenido
loading

Tabla de contenido