Preliminary Adjustments - Rubi DM-500 Manual De Instrucciones

Tabla de contenido

Publicidad

10) INDICATOR LIGHT FOR TRIGGERING OF
OVERLOAD PROTECTION
Orange light that goes on when the machine stops due to
triggering of the thermal overload protection on one of the
motors.
11) ENABLING SELECTOR FOR CUTTING LINE
LASER DEVICE (OPTIONAL)
O
1
Selector with two positions, allowing the optional laser device
for definition of cutting lines to be switched on.
11
Electrical panel (fig. 14)
The electrical panel is located on the side of the machine, and contains electrical power
components. To open the electrical panel the special key supplied with the machine
must be used.
12) MAIN SWITCH
O
Allows the machine to be turned on. During repair and
maintenance operations this switch can be locked in the O
position (machine off) by using a suitable lock inserted into the
1
slots provided.
13) WHITE INDICATOR LIGHT FOR PRESENCE OF
MAIN POWER SUPPLY
White indicator light to show the presence of the main
electrical power supply. When the light is on, power is being
supplied to the machine.
13
12
14
ENGLISH

2.- PRELIMINARY ADJUSTMENTS

Adjustment of vertical blade position
For adjusting the vertical blade position use the specific handwheel (fig.15-A) located on
the carriage head, vertical movement is indicated on the reference scale by the index
(fig.15-B) on the side of the carriage protection cover.
UP/DOWN
10
Disco
Blade
UP
Disco
Blade
DOWN
15
-22-
Selector
A
B

Publicidad

Tabla de contenido
loading

Tabla de contenido