Applications
Interior
Acoustical Ceilings
1.
Determine and mark the finished ceiling height and securely install the first piece of wall
molding to this height.
2.
Attach the laser onto the wall molding by sliding the wall mount over the wall molding
and turn the locking screws until the wall mount is secured.
3.
Make sure the locking knob on the wall mount is loose.
4.
To adjust the elevation, turn the fine height adjustment screw until the slider edge is at the zero
(0) mark on the scale (wall molding elevation), and turn the locking knob to tighten it.
Note: To minimize accidental dropping, insert a ceiling wire through the laser's handle and
twist the wire.
Drywall and Partitions
1.
Slide the laser along the elevation scale to the short line at the scale above the 0-mark.
2.
Place the laser over the near wall-control point.
Note: If the wall mount is attached to the floor track, make sure the laser is set to the edge of
the track (0-mark).
3.
Use the Left/Right arrow button to point the beam towards the far wall-control point.
4.
Go to the far wall-control point and use the remote control to adjust the line of the laser
until the laser beam is aligned to the mark.
Note: If you're using the perpendicular beam for alignment, use the RC402N menu to activate
the Beam Plunge function to move the perpendicular beam to your far wall-control mark.
Note: When the laser beam is on the mark, press the Manual button, then use the line buttons
for left and right adjustment.
Note: After line adjustment is completed, press the Manual button so the laser will
automatically re-level.
5.
Install the track or mark the track line on both the floor and ceiling for future track installation.
14