Standard Features
Rotation Mode
Rotation speed can be selected using the Rotation button as well as using the RC402N menu.
Repeatedly pressing the Rotation button toggles through 0, 10, 80, 200, 600 rpm regardless if the unit is in
automatic or manual mode. At 0 rpm, the beam stops automatically close to the +Y- axis center position.
When set up horizontally in automatic mode, using buttons Up/Down increases/decreases the rotor speed from
10 to 80 and then continuously in 10 rpm increments up to 600 rpm.
Note: The zone-scan button can be used to stop the beam's rotation.
Pointing mode
At 0 rpm, buttons Left/Right move the beam to the left/right side. When set up vertically at 0 rpm, buttons
Up/Down can be used for moving the beam clockwise/counterclockwise and to align the rotor vial.
Scan mode
Scan mode can be selected using the Scan button as well as using the RC402N menu.
Quickly press and release the Scan button to toggle between the pre-selected scan sizes 5°, 15°, 45°, 90°, 180°
and 0; regardless if the unit is in automatic or manual mode.
When working in horizontal automatic mode, press and hold button Up/Down to increase/decrease the line size
in 5° increments. Press and hold button Left/Right moves the scan line to the right/left direction.
When used in automatic vertical mode, pressing and holding button Up/Down moves the scan line
counterclockwise/ clockwise. When set up vertical, pressing and holding button Left/Right moves the scan line
into the right/left direction regardless if in automatic or manual mode. For the first 4 seconds, the scan line
moves slowly than faster.
Note: The rotation control button can be used to stop the scan mode.
11