PRO 1000 Series
Non-Progammable Thermostat
Product Information
For 1 Heat systems
TH1100DH:
For 1 Heat/1 Cool systems
TH1110DH:
For 1 Heat/1 Cool systems
TH1110E:
*TH1110E model has a larger display than pictured
For 2 Heat/1 Cool heat pump systems
TH1210DH:
Quick reference to controls
77
Set
Cool
On
Fan
E.M. Heat Heat Off Cool
Auto On
M32821
System switch
•
Cool: Cooling system control.
•
Off: All systems off.
•
Heat: Heating system control.
•
Em Heat: Emergency & Auxiliary Heat control. Compressor is locked
out. (Select models only.)
Quick reference to display screen
Setpoint indicator
Set
Appears when the setpoint
temperature is displayed
System status
Cool on: Cooling system is on.
Lo
Heat on: Heating system is on.
Batt
Aux On: Auxiliary heat is on.
(Only for heat pumps with
this capability [select models
only].)
When "Heat On" or "Cool
On" is flashing, compressor
protection is engaged.
Adjust the temperature
77
Set
Cool
On
Fan
E.M. Heat Heat Off Cool
Auto On
M32822
Need Help?
For assistance please visit
Up/Down buttons
Press to adjust temperature.
Fan Switch
On: Fan runs continuously.
Auto: Fan runs only when heating
or cooling system is on.
77
Temperature
The ambient (measured)
temperature is normally
displayed. To view the
setpoint temperature, press
Cool
the Up or Down button once.
On
The setpoint temperature
will appear for five seconds.
M32763
Low battery warning
Press s or t to adjust the
temperature.
Note: Make sure the thermostat
is set to the system you want to
control (heat or cool).
Resideo.com
Read before installing
Built-in compressor protection
This feature helps prevent damage to the
77
Set
compressor in your air conditioning or heat
pump system.
Damage can occur if the compressor is restarted
too soon after shutdown. This feature forces the
Cool
compressor to wait 5 minutes before restarting.
On
During the wait time, the display will flash the
M32769
message Cool On. When the safe wait time has
Message flashes until
elapsed, the message stops flashing and the
safe restart time has
compressor turns on.
elapsed.
CAUTION
Equipment damage hazard
To prevent possible compressor damage, do not operate cooling system
when outdoor temperature is below 50°F (10°C).
Battery replacement
W/
Not
Aux
Used
Install two fresh AAA batteries when Lo Batt
flashes on the screen. Lo Batt appears for
60 days before the batteries are depleted.
Fan
E.M. Heat Heat Off Cool
Auto On
Replace batteries once a year, or when you
M32823
will be away for more than a month.
Pull at bottom to
remove thermostat
The settings are stored in non-volatile
from wallplate.
(permanent) memory and are thus
preserved when the thermostat is without
batteries.
Product manuals
Search online for Resideo 69-2607EFS for the User Guide.
Electrical ratings
System
Voltage (50/60Hz)
Heat (1st stage)
20-30 Vac
(Powerpile)
750 mV DC
Auxiliary heat
20-30 Vac
Cooling
20-30 Vac
*
Cool
On
Fan
Heat Off Cool
Auto On
Turn thermostat over, insert
RTHXXXX
fresh AAA alkaline batteries,
then reinstall thermostat.
M32707
Running Current
0.02-1.0 A
100 mA DC
0.02-1.0 A
0.02-1.0 A
33-00529EFS-03