2.- INSTALLATION
The way the BUILT-IN FIREPLACE H-03 is installed
will decisively affect safety issues and how it
works.
It is important to install the fireplace correctly.
In order to ensure it has been installed correctly, it
should be installed by a professional.
In order to install the Built-in Fireplace H-03, a
chimney ("draw") must be installed using suitable
metal pipes and must extend at least 1 metre
above the highest part of the roof.
If a built-in chimney already exists, the said
chimney must be connected to the Cast Iron
Fireplace by means of a joint and perfected
connected to the smoke outlet on the device. (See
Fig.-2)
It is essential to seal the joints between chimney
sections.
It is mandatory to install grilles at the top of the
hood and at the bottom of the lining to allow hot
air to circulate for two main reasons:
- Provide extra hot air to the room.
- Avoid possible cracks in the lining.
HERGÓM provides 25x20 and 50x20 cm.
ornamental grilles as an option.
See the "Manual for professional installers"
attached to this one for more information on the
installation of this type of equipment.
Seal
1. Brickwork chimney.
2. Pipe connecting Fireplace to the
chimney
3. Inflow of cool air to the lining
4. Outflow of hot air to the room.