LIGHTING
POWER
LIGHTING UP FOR THE FIRST TIME
Once installed in its final position, check that all
joints have been sealed to prevent outside air from
entering, which would affect the draw.
Before lining the fireplace with bricks or any other
incombustible material, check that it works
correctly.
We recommend a slow fire for 3 to 4 hours when
lighting-up for the first time. This will help stabilise
the different components and avoid any possible
breakages.
It is advisable, when lighting the fireplace for the
first time, to open windows to let any fumes or
odours that may be caused by the combustion of
the protective paint solvents or any other material
to escape.
PRIMARY AIR. REGULATION
The provision of air for the combustion process is
performed by means of the primary air valve. (See
fig. 4)
To favour lighting-up the fireplace and to avoid the
formation of tar, we recommend opening the
primary air valve completely to allow the inflow of
abundant air for the combustion process.
This situation must be maintained at the beginning
of each lighting-up process in order to heat the
fireplace and chimney, which will avoid the
formation of condensation and creosote.
It is essential to provide an abundant load of fuel
when lighting. The following loads will depend on
the heat requirement desired.
Once the fireplace is hot, you may regulate the
provision of air for the combustion process.
COMMENT: Due to its air-tightness and heat
circulation of the Built-in Fireplace H-03 during
normal situations, we recommend opening the
door of the fireplace slowly when you have to add
more fuel.
AND
REGULATING
Fig. 6. Detail of provision of
cleaning glass pane air
Fig. 4 Detail of the provision of
primary air
DOUBLE COMBUSTION. SECONDARY AIR.
The purpose of secondary air for the combustion
process is to provide additional air to burn any un-
burnt matter after the primary combustion process
due to a lack of oxygen.
This results in double combustion and improve the
performance of the device.
The provision of secondary air is through the
bottom at the back of the fireplace. (See Fig.-5)
SELF-CLEANING
The provision of cleaning glass pane air is through
the top opening in the BUILT-IN FIREPLACE H-03
and is aimed at the glass pane on the door,
creating a layer of air that will prevent soot from
adhering to the said pane. (Self-cleaning) (See Fig.-
6)
14
Fig. 5. Detail of the provision
of secondary air