Dometic FreshJet 1100 Manual De Instrucciones página 19

Ocultar thumbs Ver también para FreshJet 1100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
FreshJet
Item
Description
5
Fan evaporator
6
Battery
7
Remote socket
8
Temperature sensor
9
Heating (FreshJet1700,2200 only)
10
Heat Pump (FreshJet2700, 3200 only)
11
Soft Start (FreshJet2200,2700, 3200 only)
Keys for fig. j:
Item
Description
1
Remote light switch
2
Circuit board in the air outlet unit
See fig. d
230 Vw cable
➤ Connect the roof air conditioner with the 230 Vw voltage supply.
Connect the cables (1) to a cable connector (2).
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
➤ Connect the two cables of the remote light switch to the 2-pin plug (3).
➤ Insert the 2-pin plug (3) into socket on the circuit board.
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
EN
Installation
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Freshjet 1700Freshjet 2200Freshjet 2700Freshjet 3200

Tabla de contenido