Dometic FreshJet 1100 Manual De Instrucciones página 21

Ocultar thumbs Ver también para FreshJet 1100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
FreshJet
Attaching the roof air conditioner
See fig. a
➤ Position the roof air conditioner into the mounting opening using the conical
noses.
Electrical connection
The complete circuit diagram can be found in fig. g:
Item
Description
1
230 Vw mains
2
Compressor
3
Fan condenser
4
Fan condenser (FreshJet2700, 3200 only)
5
Fan evaporator
6
Battery
7
Remote socket
8
Temperature sensor
9
Heating (FreshJet1700, 2200 only)
10
Heat Pump (FreshJet2700, 3200 only)
11
Soft Start (FreshJet2200,2700, 3200 only)
Keys for fig. h:
Item
Description
1
Remote light switch
2
Circuit board of the air outlet unit
See fig. b
230 Vwcable
➤ Connect the roof air conditioner with the 230 Vwvoltage supply.
Connect the cables (1) to a cable connector (2).
EN
Installation
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Freshjet 1700Freshjet 2200Freshjet 2700Freshjet 3200

Tabla de contenido