Manual Manoeuvre Or Release; Testing; Maintenance; Disposal - Nice Wingo Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37

3) Manual manoeuvre or release

The gate must be moved manually (fig.3) in case of a power failure
or a system fault.
Manual movement allows the gear motor to move freely only if this is
correctly mounted and original accessories have been used.

4) Testing

The whole system must be tested by qualified and expert staff who
must perform the tests required, according to the relative risk.
To test WINGO, proceed as follows:
• close the gate;
• disconnect the power supply from the control unit;
• release the gear motor;
• completely open the gate by hand;
• check that the gate does not stick when moving;
• check that when the gate is stopped at any point it remains
motionless;
• check that the safety system and mechanical stops are in good
condition;
• check that the screw connections are perfectly tight;

5) Maintenance

WINGO does not require any special maintenance, but a scheduled
control at least every six months will ensure the gear motor lasts
longer and that the system works correctly and safely.

5.1) Disposal

WINGO comprises various types of materials which must be
disposed of in compliance with the laws of the country of installation.
There are no particular dangers or risks deriving from demolition of
the system.

6) Technical specifications

6.1) Models and characteristics

Power input
Absorbed current
Absorbed power
Incorporated condenser
Protection level
Speed
Travel
Max. thrust
Operating temp.
Thermal protection
Work cycles
Weight
6
(Vac/Hz)
(A)
(W)
(uF)
(IP)
(m/s)
(mm)
(N)
(°C Min/Max)
(°C)
(%)
(kg)
• check that the lead nut and internally threaded screw are well
greased;
• check that the photocells are clean;
• after the above checks, block the gear motor and power the
control unit.
• WINGO does not have a torque adjustment device; this kind of
adjustment is therefore made by the control unit.
• measure the force of impact as required by EN12453 and
EN12445 standards.
Maintenance simply involves repeating the test procedure.
If waste sorting is required, the components should be grouped by
type of material (electrical, aluminium, plastic, etc.).
WG4000
230/50
0,5
120
5
44
0,016
320
1500
-20 ÷ +50
140
30
5
WG4000/V1
110/60
1
10
0,020

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wg4000Wingo wg4000/v1

Tabla de contenido