HEINE
EN200
®
Please read and follow these instructions for use and keep them for future reference.
Intended Use
The HEINE
EN200 Wall Transformer is a two–channel, dimmable 3.5 V power supply with a 5 V output
®
for medical HEINE Diagnostic Instruments. It should only be operated by trained medical staff within a
professional health facility.
For U.S. only:
Federal law restricts this device to sale by or on the order of a Physician or Practitioner!
Warnings and Safety Information
CAUTION! Indicates potential hazardous situations. Ignoring the corresponding instructions may lead
to dangerous situations of mild to moderate extent. (Background color yellow; foreground color black).
NOTE! Indicates valuable advice in terms of installation, operation, maintenance or repair. Notes are
important, but not related to hazardous situations.
Assembly and disassembly
Assembly accessories
Allen wrench 1.3
To ensure all-pole disconnection from the mains at all times, the ME device must be installed so that
the switch mode power supply is accessible and disconnectable.
Before mounting the device, check whether you need to use a special wall plug for the subsurface of
your wall and whether the subsurface exhibits sufficient load-bearing capacity for the meachnical stress.
The wall plugs supplied with the product are universal wall plugs and suitable for most building
materials (e.g. concrete, solid brick, brick).
1. Hold the drill template horizontally in place on the desired position and mark the drill holes. Drill a hole of
at least 40 mm deep using a Ø 6 mm drill.
2. Fit wall plugs.
3. Use a suitable screwdriver to tighten the two upper screws with a distance of approx. 3 mm to the wall.
4. Hang the device – disconnected from the mains – on the two screw heads, press firmly and push
downwards. Check to make sure that the device is correctly positioned on both screw heads.
5. Screw in the two lower screws.
To disassemble, disconnect the device from the mains first, loosen the two lower screws, push upwards and
take off the wall.
USB connector
The device has an USB interface on its rear side as power supply for additional medical diagnostic
instruments from HEINE.
Connect the HEINE USB cord and run the cable via the housing canal to the outside on the left or right hand
side. To do so, press the cable into the clamping hubs, which act as strain relief.
Setting up
Primary plug
EU
USA / Japan
The device may only be operated with the mains voltage specified on the nameplate of the power supply.
- Attach the primary plug to the plug-in transformer until it engages.
- Connect the device to the mains with the plug-in transformer. The green indicator light on the EN200
illuminates.