4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter (INP A)
30 Hz filter off (f
30 Hzfilter on
4.3 Multiplying factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.4 Dividing factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.5 Decimal point
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
0.0
0.00
0.000
B
)
max
no decimal place
one decimal place
two decimal places
three decimal places
4.6 RESET mode (totaliser 1)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
4.7 RESET Mode (totaliser 2)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
4.8 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.