5. Technical data
Supply voltage
AC power supply: 100 ... 240 VAC/max. 6 VA
Tolerance ±10%, 50/60 Hz
ext. fuse protection: T 0.1 A
DC power supply: 10 ... 30 V DC/max. 50 mA
with inverse-polarity
protection
SELV, CLASS II
(Limited Power Source)
ext. fuse protection: T 0.1 A
Display:
6 digits, red 7 segment
LED display, height 14 mm
Data retention:
EEPROM
Polarity of the inputs:
Programmable, npn or pnp
for all inputs
Input resistance: appr. 5 kW
Count frequency:
AC power supply: 100 ... 240 VAC ±10%
Input level:
typ. low level:
typ. typ. high level:
Fmax:
tot.tac
tot.tot
1)
tot.ti
2)
tot.ti
1)
Start Gate.Lo Inp B not activ
2)
Start InpB.InpB and Inp B connected
with Inp A
DC power supply:
Input level:
typ. low level:
typ. ligh level:
Fmax:
tot.tac
tot.tot
1)
tot.ti
2)
tot.ti
1)
Start Gate.Lo Inp B not activ
2)
Start InpB.InpB and Inp B connected
with Inp A
Page 12 | ENG
standard
5V
2,5 V
1,0
22,0 V
4,0 V
kHz
kHz
35
35
60
50
35
30
15
15
24
12 V DC 0 ...30 V DC
Standard
2,5
2,0 V
1,0 V
22,0
10 V
4,0 V
kHz
kHz
kHz
35
20
60
20
40
20
15
10
Frequency measurement:
Accuracy :
Measuring principle:
< 38 Hz:
> 38 Hz:
In case of frequencies < 10 Hz, the waiting time
must be increased accordingly to obtain the
display of a value.
Time count ranges:
Seconds
Minutes
Hours
h.min.s
Accuracy
Minimum pulse length for the Reset input:
Switching level:
Standard level (HTL):
AC power supply
DC power supply
4 ... 30 V DC level: Low: 0 ... 2 V DC
Pulse shape:
Sensor supply voltage:
(Voltage output for external sensors)
SELV circuit, reinforced/double insulation
AC power supply
5V
Ambient temperature:
Storage temperature:
8
8
8
EMC:
8
Noise emission:
Noise immunity:
< 0.1 %
period measurement
gating time measurement
gating time = 26,3 ms
0,001 s ... 999 999 s
0,001min ... 999 999 min
0,001 h ... 999 999 h
00 h 00 min 01 s
... 99 h 59 min 59 s
<50 ppm
5 ms
Low: 0 ... 4 V DC
High: 12 ... 30 V DC
Low: 0 ... 0,2 x U
[V DC]
B
High: 0,6 x U

... 30 [V DC]

B
High: 4 ...30 V DC
any,
Schmitt-Trigger inputs
24 V DC ±15 %/100 mA
–20 ...+65 °C
–25 ... +70 °C
EN 55011 Class B