O-Ring
5. Assemble the Adapters and Unions
NOTICE: Do not apply excessive heat near the valve or apply flux or acids directly onto the valve. This
valve contains plastic and rubber components which will melt if heat is directly applied.
Disassemble the adapter. Ensure all rubber and plastic components are removed.
Slide the union nut onto the inlet/outlet tube.
Solder the inlet/outlet tube to the union. Allow to cool completely.
Assemble the union.
Slide the adapter nut onto the inlet/outlet tube.
Assemble the adapter lock onto the inlet/outet tube and slide the assembly into the adapter nut.
Slide the O-ring onto the inlet/outlet tube.
For inlet tubes only: Insert the screen into the end of the inlet tube.
Reinstall the adapter assembly to the valve.
Repeat for all inlet/outlet tubes as required.
1145587-2-A