Specifications
Pressures
Maximum Static Pressure
Supply Pressure Differential*
Minimum Flow Rate
Temperatures
Programmable Temperature
Default Temperature at Start-up
Minimum Mixed Temperature
Differential from Hot Supply
Temperature Stability at Recommended
Supply Conditions
Ambient Temperature
Maximum Relative Humidity
Electrical
Electrical Service
User Interface Cable Length (supplied)
* In commercial applications where there is a large difference in hot and cold supply pressures or frequent
fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be
installed.

Tools and Materials

Adjustable
Level
Wrench
Pencil
Screwdrivers
Kohler Co.
125 psi, 862 kPa, 8.6 bar
Max 5 psi, 34.5 kPa, 0.34 bar (Equal pressures recommended.)
1.6 gpm (Less than 72 psi dynamic pressure.)
6 lpm (Less than 500 kPa maintaining pressure.)
2.1 gpm (Greater than 72 psi dynamic pressure.)
8 lpm (Greater than 500 kPa maintaining pressure.)
Max 120°F (49°C) Min 86°F (30°C) Full cold may also be selected.
100°F (38°C)
3.6°F (2°C)
+/- 1.6°F (1°C)
Greater than 34°F (1°C), Max 104°F (40°C)
95% non-condensing
120 V, 15 A, 60 Hz
20 ft (6.1 m)
Drill
Solder
Pipe Wrench
Hacksaw or Tube Cutter
Plus:
• (2) 1/2" Union Connectors
• Wood and Framing Materials
• PEX Tubing, Copper Tubing, or PVC
• (2) Water Hammer Arrestors (Recommended)
Propane
• (2) Supply Shut-Off Valves
Torch
Wood Saw
3
Hammer
Sealant
Tape
1145587-2-A