ENGLISH
DC Current Measurement
Range
Resolution
400µA
0.1µA
2000µA
1µA
40A
0.01A
400A
0.1A
Overload Protection:
600V RMS
Voltage:
•
Current:
2000µA
•
AC Current Measurement
Range
Resolution
400µA
0.1µA
2000µA
1µA
40A
0.01A
400A
0.1A
Overload Protection:
Voltage:
600V RMS
•
Current:
2000µA
•
45 to 400Hz
Frequency:
Minimum Current for Frequency Measurement:
True RMS
Response:
Resistance Measurement
Range
Resolution
400 Ω ˜ 4M Ω
0.1 Ω ˜ 0.001M Ω
40M Ω
0.01M Ω
Overload Protection:
600V RMS
Capacitance Measurement
Range
Resolution
40nF ˜ 4000µF
0.01nF ˜ 1µF
Overload Protection:
600V RMS
Frequency Measurement
Range
Resolution
9.999Hz ˜ 999.9kHz
0.001Hz ˜ 0.1kHz
600V RMS
Overload Protection:
Duty Cycle Measurement
Range
Resolution
0.1 ˜ 99.9%
0.1%
Overload Protection:
600V RMS
Diode Test
Overload Protection Range
600V RMS
2.0V
Accuracy
± (1.2% + 3 digits)
± (2.5% + 15 digits)
± (1.5% + 8 digits)
Accuracy
± (2.0% + 5 digits)
± (1.5% + 5 digits)
± (2.9 % + 15 digits)
± (1.9% + 8 digits)
400µA or 20A
Accuracy
± (1.0% + 4 digits)
± (2.0% + 4 digits)
Accuracy
± (3.5% + 6 digits)
Accuracy
± (0.1% + 4 digits)
Accuracy
± (0.2% per kHz + 0.1% + 5 digits)
Test Current
Open Circuit Voltage
Appx. 0.25mA
< 1.6V DC
WARRANTY
This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,
Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.
This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper
maintenance. Batteries and damage resulting from failed batteries are not
covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state. If your Klein product requires
repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-877-775-5346.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
STORAGE