ENGLISH
4.
Frequency (Hz) / Duty Cycle (See Feature Details)
Features:
HOLD
• Select ,
, or
setting.
• Frequencies greater than 1MHz will display "0.000Hz".
Resistance: < 40M Ω
5.
Features:
HOLD
RANGE
•
Do not measure resistance on a live circuit.
Capacitance: < 4000µF
6.
Features:
HOLD
•
Safely discharge capacitor before measurement.
• Reading may take up to 60 seconds for large capacitors.
7.
Diode / Continuity
Diode Features:
0
10
20
30
40
Display shows:
• Forward voltage drop if forward biased.
• "O.L." if reverse biased.
Continuity Features:
0
10
20
30
40
• Display shows resistance.
• Buzzer sounds if less than 30 Ω .
PRESS
0
10
20
30
40
Duty
Hz
Cycle
MAX/MIN
0
10
20
30
40
0
10
20
30
40
PRESS
TO SELECT
Diode
Continuity
HOLD
MAX/MIN
HOLD
MAX/MIN
Non Contact Voltage (NCV): > 25V AC
8.
PRESS
and
HOLD
SYMBOLS USED ON LCD
~
AC Measurement
-
Negative DC Value
O.L.
Overload: Range Exceeded
Low Battery
MIN
Minimum Reading
%
Duty Cycle Mode
V
Voltage Measurement
Ω
Resistance in Ohms
F
Capacitance in Farads
Relative / Zero Mode
µ
Micro 10
-6
k
Kilo 10
3
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
400mV ˜ 400V
0.1mV ˜ 0.1V
1000V
1V
Overload Protection:
1000V
AC Voltage Measurement
Range
Resolution
400mV ˜ 750V
0.1mV ˜ 1V
Overload Protection:
750V RMS
Frequency Response:
40 to 400Hz
Minimum Voltage for Frequency Measurement:
Response:
True RMS
Continuity Test
Overload Protection
600V RMS
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
PRESS
and
HOLD
DC Measurement
AT
Auto Range Active
Apo
Auto Power-Off Active
Hold Active
HOLD
MAX
Maximum Reading
Frequency Mode
A
Current in Amps
Diode Test
Continuity Test
n
Nano 10
-9
m
Milli 10
-3
M
Mega 10
6
Accuracy
± (0.5% + 4 digits)
± (0.8% + 10 digits)
Accuracy
± (2.0% + 5 digits)
200mV
Open Circuit Voltage
< 0.44V