Cyrix-ct 12/24V and 24/48 -120A intelligent battery combiner
No voltage loss
The Cyrix-ct battery combiner is a microprocessor controlled heavy duty relay that
automatically connects batteries in parallel when one battery has reached a preset
voltage (indicating that the battery is being charged), and disconnects when the voltage
decreases below float level (indicating that one or both batteries are being discharged).
Cyrix battery combiners are an excellent replacement for diode isolators. The main
feature is that there is virtually no voltage loss so that the output voltage of alternators
or battery chargers does not need to be increased.
Temperature protected
In case of over temperature due to high ambient temperature and/or due to excessive
current, the Cyrix-ct will open. It will resume normal operation after cooling down.
Prioritising the starter battery
In a typical setup the alternator is directly connected to the starter battery. The
accessory battery, and possibly also a bow thruster and other batteries are each
connected to the starter battery by Cyrix battery combiners. When a Cyrix senses that
the starter battery has reached its connect voltage it will engage, to allow for parallel
charging of the other batteries.
Bidirectional voltage sensing
The Cyrix senses the voltage of both connected batteries. It will therefore also engage if
for example the accessory battery is being charged by a battery charger.
Intelligent battery monitoring to prevent repeated switching
The software of the Cyrix-ct 120 does more than simply connect and disconnect based
on battery voltage and with a fixed time delay. The Cyrix-ct looks at the general trend
(voltage increasing or decreasing) and reverses a previous action only if the trend has
reversed during a certain period of time. The time delay depends on the voltage
deviation from the trend.
12/24 and 24/48 Volt auto ranging
The Cyrix-ct will automatically adjust to a 12V, 24V, 48V system.
Installation (see figure below)
1.
The Cyrix can only be used in 12V, 24V or 48V installations with a negative
common.
2.
Disconnect the minus of both batteries.
3.
Place the Cyrix closest to the smallest battery (in general the starter battery).
4.
Connect the plus of the batteries to the brass bolts of the Cyrix, marked with no 30
resp. 87. Install a fuse in series (see fig). The fuse should be sized in accordance
with the wire cross section used, but not exceed 120A.
Connect the minus of the Cyrix "battery –" (86) and reconnect the minus of both
5.
batteries.
An emergency start push button can be wired to "start assist" connection (85) if
6.
required. The relay will engage during 30 seconds after "start assist" has been
momentarily connected to the battery plus. Alternatively, a parallel connect switch
can be used to engage the relay as long as the switch remains closed.
LED status indication
Continuous current
Cranking rating (5 seconds)
Current consumption when open
Current consumption when closed
Start Assist
Protection category
Weight
Dimensions (h x w x d)
Approximate connect and disconnect delay
(multiply by two for a 24 V system)
Connect (V)
Delay
V < 13 V
Remains open
13,0 V < V < 13,2 V
10 min
13,2 V < V < 13,4 V
5 min
13,4 V < V < 13,6 V
1 min
13,6 V < V < 13,8 V
4 sec
Phone: (+31) (0)36 535 97 00 / Fax: (+31) (0)36 535 97 40 /
ENGLISH
Cyrix-ct 12/24-120
No
120 A
180 A
<4 mA
12 V : 220 mA
24 V : 120 mA
Yes (Cyrix remains engaged during
30 seconds)
IP54
0,11 kg (0.24 lbs)
46 x 46 x 80 mm
(1.8 x 1.8 x 3.2 inch)
Disconnect (V)
V < 11 V
11,0 V < V < 12,0
V
12,0 V < V < 12,2
V
12,2 V < V < 12,4
V
12,4 V < V < 12,8
V
> 12,8 V
remains closed
> 16 V
Victron Energy bv / De Paal 35 / 1351 JG ALMERE / The Netherlands
Cyrix-ct 12/24 en 24/48 -120 intelligent battery combiner
Geen spanningsverlies
De Cyrix-ct bestaat uit een microprocessor gestuurd power relais dat accu's
automatisch van elkaar loskoppelt wanneer de spanning daalt tot onder een bepaalde
waarde (een teken dat de accu's niet geladen worden), en weer parallel schakelt
wanneer de spanning over één van de accu's stijgt tot boven een bepaalde waarde
(een teken dat de accu geladen wordt).
De Cyrix accuscheider is een uitstekend alternatief voor diode of FET laadstroom
verdelers. Het spanningsverlies is namelijk praktisch nihil.
Temperatuur beveiliging
Schakelt af indien de temperatuur te hoog wordt ten gevolge van hoge omgevings-
temperatuur en/of te hoge stroom. Schakelt weer in na afkoeling.
Voorrang voor de startaccu
De startaccu mag nooit leeg raken. Het is daarom gebruikelijk om de dynamo op de
startaccu aan te sluiten. Andere accu's, zoals de accessoire accu, en (in een boot)
mogelijk ook de boegschroef accu kunnen vervolgens met een Cyrix accuscheider op
de startaccu aangesloten worden. De Cyrix accuscheiders zorgen er dan voor dat alle
accu's parallel geschakeld worden zodra de spanning van de startaccu voldoende
gestegen is.
Bidirectioneel
De Cyrix meet de spanning over alle twee de aangesloten accu's. De accu's zullen
dus ook parallel geschakeld worden wanneer de accessoire accu geladen wordt,
bijvoorbeeld met een acculader.
Intelligente accuspanning bewaking om herhaald schakelen te voorkomen
De software van de Cyrix-ct 120 kijkt naar de trend van de accuspanning (spanning
stijgt of daalt) en schakelt pas als de trend gedurende een bepaalde tijd is
omgekeerd.
De tijd is langer naarmate de spanningsafwijking geringer is.
Geschikt voor 12V, 24V en 48V accuspanning
De Cyrix-ct past zich automatisch aan aan de 12V, 24V of 48V systeemspanning.
Installatie (zie schema)
1. De Cyrix is alleen geschikt voor 12V, 24V en 48V installaties met een negatieve
massa.
2. Maak de min polen van beide accu's los.
3. Plaats de Cyrix dicht in de buurt van de kleinste accu (iha de startaccu).
4. Verbind de plus polen van de 2 accu's respectievelijk met aansluiting 30 en 87
(de bout aansluitingen). Installeer ook een serie zekering (zie fig). De waarde van
de zekering moet afgestemd zijn op de gebruikte draaddoorsnede en mag niet
meer dan 120A bedragen.
5. Verbind de min aansluiting "battery –" (86) en sluit de minnen van de accu's
weer aan.
6. Noodstart drukknop. Indien pen "start assist" (85) kort met de accu plus
verbonden wordt zal het relais gedurende 30 seconden sluiten. Indien een
schakelaar gebruikt wordt ipv een drukknop zal het relais gesloten blijven zolang
de schakelaar gesloten is.
Delay
0 sec
1 sec
10 sec
30 sec
3 min
over voltage
disconnect
www.victronenergy.com
Revision : Rev 03
Date
NEDERLANDS
/ e-mail: sales@victronenergy.com
: 15-04-2014