NOTE!
Ensure to use a fitting thread (see accessories).
`
`
Screw the thread by hand and without any force.
3. Screw the discharge hose onto the connecting
thread of the pump .
4. Attach the gas-shuttle pipe to the thread of the bar-
rel screw joint  and screw it together finger-tight
using the cap nut.
5. Attach the gas-shuttle pipe to the thread of the
discharge hose  and screw it together finger-tight
using the cap nut.
NOTE!
`
`
Check the hose connections and seals regularly
for position and tightness.
Safe filling
CAUTION!
Liquid entering the instrument. Bodily injury due to
escaping liquid and damage to the instrument.
`
`
Do not overfill the filling container.
`
`
Do not fill off when the shut-off valves are closed.
1. Open the shut-off valves on the discharge hose and
the gas-shuttle pipe.
2. Press the filling cone  into the opening of the
filling container to form an airtight seal. The filling
cone has to be pressed onto the container during
the whole filling process.
Accessories
Type
Antistatic set
SafetyBox
More accessories can be found at www.buerkle.de
Troubleshooting
Problem
Liquid is not pumped.
Specification
To prevent electrostatic charging
Incl. safety goggles and protective gloves
To eliminate the error
Bottom valve is polluted. Clean the pump.
The telescopic riser pipe does not extend into the liquid being filled.
Open the shut-off valves.
If there is only little residual liquid in the container, the pumping must be carried
out for a longer time.
NOTE!
Only filling containers with round shaped openings
and a diameter of 18 to 49 mm can be used.
3. Activate the piston rod  by using the handle
and fill off the liquid. Thereby, the displaced air is
returned from the filling container to the original
container via the gas-shuttle pipe.
Completing filling and dismounting
1. After the last pump stroke, leave the piston rod in
the lower position and insert it into the pump up to
the stop.
2. Close both shut-off valves.
3. To prevent any liquid continue to run (siphoning
principle), fix the discharge hose above the liquid
level in the original container.
WARNING!
Some liquid will continue to run. Bodily injury due
to escaping liquid.
`
`
Close the shut-off valves on the discharge tube
and the gas-shuttle pipe before dismounting.
`
`
Raise the discharge hose and allow the liquid to
run back into the container.
4. Carefully remove the pump from the original con-
tainer and allow the remaining liquid to drain into
the filling container.
5. Allow the remaining vapours to escape out of the
instrument and rinse the instrument with a pH-neu-
tral liquid.
English
Number
Item No.
1
5602-1000
1
2507-9000