CONVERTIBLE JET PUMP INJECTOR KIT
APPLICATION
For shallow wells down to 25 ft ( 7.6 m; injector is bolted to the casing)
For deep wells from 25 to 90 ft (7.6 to 27.4 m; injector is retrofitted and installed in the well)
TOOLS REQUIRED
Attaching injector to pump - 3/8" wrench (shallow well application only)
Venturi removal - 5/8" hex key or socket bit (medium deep and deep well applications only)
Venturi replacement - 5/8" wrench (medium deep and deep well applications only)
Nozzle removal - 3/4" deep socket (medium deep and deep well applications only)
Locate the applicable pumping depth below and follow the installation instructions for that depth.
Pumping
Application
Depths
Maximum depth:
Shallow Well
25 ft (7.6 m)
Medium Deep Well
25 - 30 ft
down to 30 ft
(7.6 - 9.1 m)
(9.1 m)
Medium Deep Well
30 - 60 ft
down to 60 ft
(9.1 - 18.3 m)
(18.3 m)
Deep Well
60 - 90 ft
down to 90 ft
(18.3 - 27.4 m)
(27.4 m)
FOR RJC-50-PREM AND RJC-75-PREM
Part No. / Color
Injector
Location
Venturi
247288 - Brown
Bolted to pump
(factory assembled)
Above the foot valve
installed in the well
247300 - Purple
to a maximum depth
of 35 ft (10.7 m)
Above the foot valve,
installed in the well
247261 - Blue
to a maximum depth
of 65 ft (19.8 m)
Above the foot valve,
installed in the well
247281 - Green
to a maximum depth
of 95 ft (29 m)
EN
Installation Instructions
Nozzle
Installation Instructions
The injector assembly supplied in this kit is
pre-assembled for shallow well use. It contains
469022 - Green
a brown venturi installed over a green nozzle.
(factory assembled)
For shallow wells, the injector assembly will get
bolted to the pump case as is.
For medium-deep wells (25 to 30 ft or 7.6 to 9.1 m)
remove both the brown venturi and the green nozzle
from the injector assembly. Install the blue nozzle into
247292 - Blue
the injector assembly. Install the purple venturi over
the blue nozzle (see Fig. 1). The injector assembly will
get mounted in the well.
For medium deep wells (30 to 60 ft or 9.1 to 18.3 m)
remove both the brown venturi and the green nozzle
from the injector assembly. Install the blue nozzle into
247292 - Blue
the injector assembly. Install the blue venturi over the
blue nozzle (see Fig. 1). The injector assembly will get
mounted in the well.
For deep wells (60 to 90 ft or 18.3 to 27.4 m) remove
both the brown venturi and the green nozzle from
the injector assembly. Install the blue nozzle into the
247292 - Blue
injector assembly. Install the green venturi over the
blue nozzle (see Fig. 1). The injector assembly will get
mounted in the well.
ENGLISH

Publicidad

loading

Resumen de contenidos para red lion RJC-50-PREM

  • Página 1 ENGLISH CONVERTIBLE JET PUMP INJECTOR KIT FOR RJC-50-PREM AND RJC-75-PREM Installation Instructions APPLICATION • For shallow wells down to 25 ft ( 7.6 m; injector is bolted to the casing) • For deep wells from 25 to 90 ft (7.6 to 27.4 m; injector is retrofitted and installed in the well) TOOLS REQUIRED •...
  • Página 2 FRANÇAIS KIT D’INJECTEUR DE POMPE À JET CONVERTIBLE POUR RJC-50-PREM ET RJC-75-PREM Directives d’installation APPLICATION • Pour un puits peu profond de jusqu’à 25 pi (7,6 m; injecteur boulonné au boîtier) • Pour un puits peu profond de 25 à 90 pi (7,6 à 27,4 m; l’injecteur est converti et installé dans le puits) OUTILS REQUIS •...
  • Página 3 ESPAÑOL INYECTOR DE BOMBA A CHORRO CONVERTIBLE PARA RJC-50-PREM Y RJC-75-PREM Instrucciones de instalación APLICACIÓN • Para pozos poco profundos de hasta 7.6 m (25 pies; inyector atornillado al revestimiento) • Para pozos profundos de 7.6 a 27.4 m (25 a 90 pies; el inyector está acondicionado e instalado en el pozo) HERRAMIENTAS REQUERIDAS •...
  • Página 4 NOTE: The injector assembly location should be 5 ft (1.5 m) below the water level of the well to maximize performance. The foot valve, which must be submerged at all times, is recommended to be placed 5 ft below the injector. The distance from the injector to the foot valve may be increased for slower producing wells.