Programming The Operation Logic; Important - V2 ELETTRONICA PRGU433PP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PROGRAMMING THE OPERATION LOGIC

Several operation logic options are available for the control unit, by properly selecting the
position of the dipswitch positions on the board. The following table illustrates the
functions that pertain to every single dipswitch.
SWITCH FUNCTION
1
Pre-blinking (2 sec.)
2
Automatic closing
3
Start while opening
4
Start command logic
5
Slowing down
6
Photocell

IMPORTANT:

• The photocell can never be disabled during the closing.
• When using the automatic closing function (dip switch 2 ON) it is advisable to set
dip-switch 4 in OFF position. This prevents a START command to stop the
automation during the closing process.
POSITION
DESCRIPTION
ON
Active
OFF
Non-active
ON
Active (after T.PAUS.)
OFF
Non-active
ON
Not received
OFF
Received
ON
Step-by-step function
START while opening command
OFF
activates closing
ON
Active
OFF
Non-active
ON
Active also while opening
OFF
Non-active while opening
15