Troubleshooting (cont.)
(If Equipped) Chromatherapy Troubleshooting Table
Symptom
(If Equipped) Heated Surface Troubleshooting Table
Symptoms
1.
Heated surface does not
turn on.
2.
Bath is on, but there is
little or no heat.

Warranty

ONE-YEAR LIMITED WARRANTY
KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year
from date of installation.
Kohler Co.
Probable Cause
B. User interface does not work
properly.
C. Chromatherapy or user interface
cable connections are loose or
damaged.
D. If none of the recommended
actions correct the problem,
contact Kohler Co.
Probable Cause
A. No power to the power supply.
B. Heated surface control must be
reset.
C. User interface cable connections
are loose or damaged.
D. Bubble control does not work.
E. Heated surface control does not
work.
F.
Power supply does not work.
G. User interface does not work.
A. Heater cable loose or damaged.
B. Bath heater/insulation loose.
C. Heat indicator is set to low heat. C. Press the plus [+] icon to increase
D. Heater does not work.
E. Temperature sensor does not
work.
15
Recommended Action
B. Cycle through the Chromatherapy
light functions. If the lights do not
cycle through all colors and the
blue icon on the user interface is
not lit, replace the user interface.
C. Inspect the cables for loose
connections or damage. Replace the
cables as needed.
D. Contact the Customer Care Center
using the contact information on
the back cover.
Recommended Action
A. Set/reset GFCI or RCD breaker;
check wiring and power supply
connections.
B. If the red LED on the heated
surface control is not blinking,
unplug the control for 30 seconds,
then plug in and restart.
C. Inspect the cables between the user
interface, heated surface control,
bubble control, and control
amplifier. Secure connections or
replace cables as needed.
D. If the red LED on the bubble
control does not blink following
restart, check the bubble control
and replace as needed.
E. Check the heated surface control.
Replace as needed.
F.
Check the power supply. Replace
as needed.
G. Check the user interface. Replace as
needed.
A. Inspect the cables between the user
interface, heated surface control,
and control amplifier. Secure
connections or replace cables as
needed.
B. Secure heater/insulation to bath.
temperature.
D. Replace the heater.
E. Replace the heater.