Troubleshooting (cont.)
Troubleshooting Table
Symptom
(Optional) Chromatherapy Troubleshooting Table
Symptom
1.
Chromatherapy lights do
not work.
2. Chromatherapy lights do
not cycle through all
colors.

Warranty

Kohler
Produtos para Cozinhas e Banheiros Ltda Acrylic One-Year Limited Warranty
®
KOHLER Produtos para Cozinhas e Banheiros Ltda. (hereinafter referred to as KOHLER Brazil) acrylic
products, built to the highest global standards, incorporating the experience and tradition of more than a
Kohler Co.
Probable Cause
H. The user interface does not
work.
Probable Cause
A. Power to the control amplifier is
off.
B. Control amplifier must be reset.
C. Chromatherapy feature has not
been selected on the user
interface.
D. Chromatherapy or user interface
cable connections are loose or
damaged.
E. Control amplifier does not
work.
F.
User interface does not work.
G. Chromatherapy control does not
work.
A. Control amplifier must be reset.
B. Chromatherapy or user interface
cable connections are loose or
damaged.
C. Control amplifier does not
work.
D. User interface does not work.
E. If none of the recommended
actions correct the problem,
contact Kohler Co.
English-13
Recommended Action
H. Replace the user interface.
Recommended Action
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
C. Select the Chromatherapy feature
on the user interface.
D. Inspect the cables for loose
connections or damage. Secure or
replace cables as needed.
E. If the red LED on the control
amplifier does not blink following
restart, check the control amplifier
and replace as needed.
F.
Verify that the user interface cable
is securely connected to the user
interface and the control amplifier
terminal. If the connections are
good, replace the user interface.
G. Replace the Chromatherapy
control.
A. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
B. Inspect the cables for loose
connections or damage. Secure or
replace cables as needed.
C. If the red LED on the control
amplifier does not blink following
restart, check the control amplifier
and replace as needed.
D. Cycle through the Chromatherapy
light functions. If the lights do not
cycle through all colors and the
blue icon on the user interface is
not lit, replace the user interface.
E. Contact the Customer Care Center
using the contact information on
the back cover.
1181168-BR5-A