OPERATION
Controls
The light switch turns the halogen lights on
and off.
The blower on / off switch turns the blower on
to the running speed set by the blower speed
control. The blower must be turned on and off
using this switch.
The blower speed control changes the run-
ning speed of the blower. It is infinitely
adjustable from low to high speed.
The pilot lamp lights up whenever the blower
is on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
HALOGEN BULBS
This range hood requires four (4) halogen bulbs
(Type GU10, MR16 shielded, 120V, 50W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
1. Loosen the ring nut by turning it
counterclockwise.
2. Loosen
the
counterclockwise; pull the bulb downwards
to remove. CAUTION: BULB MAY BE
HOT!
3. Replace with Type GU10, MR16 shielded,
120V, 50W halogen bulb.
bulb
by
turning
- 10 -
BLOWER
SPEED
CONTROL
LIGHT
SWITCH
it
BLOWER
ON / OFF
SWITCH
PILOT
LAMP
BULB
RING NUT