GE ADQ12 Manual Del Propietario E Instrucciones De Instalación página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5
INSTALL THE CASE IN THE
WINDOW
Carefully slide the case into the window
A
and center the case. Lower the window
behind the top mounting rail. Pull the
bottom of the case forward so that the
bottom mounting rail is tight against the
back of the window stool. Mount the case
to the window sill using 2 Type D Screws.
Type D screws
Stool
Stuff the window stool seal between the
B
bottom of the case and the window stool.
Thread a Type F bolt about 1/2 of the way
C
into the outer face of the shortest angle of
both the left and right support.
Type F bolt
Type F bolt
Position the supports on the case bottom
D
so that they will be near the outside wall.
Attach the left support to the left bottom
and the right support to the right bottom
of the case using Type E bolts, 2 on
each side.
Installation Instructions
Left support
14
5
INSTALL THE CASE IN THE
WINDOW (CONT.)
Adjust the Type F leveling bolts against the
E
outside wall so that the case has a slight
tilt to the outside. Use a level; about a 1/2
bubble will be the correct case slant to the
outside.
Use a wood block between the leveling
F
bolts and the wall if the wall is weak or if
the weight of the air conditioner falls
between the studs in the wall.
Extend the left and right accordion panels
G
to the vertical window sashes. Drill pilot
holes and attach the top and bottom
corners with 4 Type C screws.
Top mounting rail
Type C
screw
Type C
screw
Type C
screw
Type C
screw