4
Technical specifications and accessories
Type: MPA−MPM−PI
Number of valve locations
Current consumption per solenid
coil at 24 V
Rated pick−up current/duration
Rated current with current
reduction
Control voltage:
Rated value (protected against
incorrect polarity)
Tolerance
Protection class as per DIN 40050
Protection against electric shock
Ambient temperature
Storage temperature
Electromagnetic compatibility
Interference emitted
Immunity to interference
1) Dimensions and materials: See Pneumatics Manual
2) Maximum 24 valve solenoid coils can be controlled
3) The valve terminal is intended for industrial usage
4) The maximum permitted signal cable length is 10 m
20
1)
MPA1
4, 8, 12...24
80 mA/25 ms
18...25 mA
24 V DC
± 25 % (18...30 V DC)
IP65 (fitted completely)
By the use of PELV current
circuits (protection against direct
and indirect contact as per
IEC/DIN EN 60204−1)
− 5 ... + 50 °C
− 20 ... + 40 °C
Tested as per EN 61000−6−4
(industry)
4)
Tested as per EN 61000−6−2
(industry)
MPA2
2)
2, 4, 6...24
105 mA/50 ms
16...22 mA
3)
Festo MPA−... 0412NH English