70
THERMEX PRO LINK II
INSTALLING THE TRANCIEVER ON LYON ISLAND
On the suspended Lyon, the Top Link receiver is installed in the junction box located inside behind the filters. The transceiver is installed as
follows:
1
Push the lower part of the duct upwards.
4
Connect the circuit board's connector to the con-
nector on the transceiver.
7
Mount the cover on the junction box to protect the
circuit board's connector from moisture and dirt.
CONNECTION BETWEEN TRANSCEIVER AND RECEIVER
Once the transceiver and receiver are connected, the two devices must be connected to each other. One transceiver can be connected up to a maxi-
mum of five receivers.
The connection must be performed as follows:
1.
Hold the "Pair" button on the receiver down for about 3 seconds, until the green "Power" LED starts flashing.
2.
Hold the button for connection to the transceiver down for about 3 seconds. The "indicator for connection" LED will start to flash when the button
is released.
2
A small junction box is located inside behind
the duct. Remove the cover from this box. This
easiest way to do this is to use a screwdriver or
similar tool to gently coax the cap off.
5
Mount the connector for the control panel on the
transceiver.
8
Mount the box containing the transceiver in a
suitable fixed position inside the hood. Use the
double adhesive tape supplied for this.
NOTE: Be sure to wipe the surface thoroughly
with alcohol before mounting the transceiver in
its fixed position.
M 536991501911122018
3
Separate the connector located in the junction
box.
6
x4
x4
Mount the cover on the plastic box containing
the transceiver using 4 screws. Mount the plas-
tic plugs on the screws.