Pro Link Premium - THERMEx PRO LINK II Serie Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

72
THERMEX PRO LINK II
Pro Link Premium is the solution for cooker hoods with an externally placed exhaust. Most ventilation systems have a limited option to run in
unbalanced operation, whereby the system cannot provide sufficient air while the hood is being used.
Thermex has therefore designed Pro Link Premium, which consists of Pro Link Basic and a motorised valve that is connected to the air supply
side of the ventilation system. When the ventilation system cannot provide sufficient air, the valve opens automatically and ensures that the
air change in the house is balanced.
When installing Pro Link Premium it is possible to mount the valve using the air supply directly from the outside or by connecting the valve to the
ducting of the ventilation system. Follow the sections that match the type of installation you have chosen in these instructions.
NOTE: Always follow the instructions of the supplier of the ventilation system when connecting Pro Link Premium.
VENT
VALVE MOTOR
1
x1
Make a measurement for mounting the valve
motor bracket onto the flange of the vent.
NOTE: Take special care to ensure that the
MOUNTING OF VALVE MOTOR
bracket is centred.
The valve motor must be mounted on the valve prior to installing the vent. This is performed in the following steps:
1
1.
2.
2
1
2
2
1.
Stop for forced operation
2.
Stop for basic ventilation
3.
Valve motor
3
Mount the bracket of the valve motor onto the
flange of the valve using the self-tapping screw.
Flange for the valve motor
Vent
x1
M 536991501911122018
3
Install the valve motor by mounting it on the
valve shaft, and follow this by attaching the
motor to the bracket.

Publicidad