9.1
Your Ceiling Fan/Light Control consists of Wall
Mounted Transmitter and a Receiver located inside
the Ceiling Cover. The Control is designed to remotely
operate your Ceiling Fan speed, light intensity and
direction of rotation.
9.2
Your Wall Control has Code Switches which must
be set in One of 32 possible code combinations
(Figure 31). The Five Levers (numbered 1, 2, 3, 4,
and 5) on the Switches are factory-set in the ON (up)
position. Change the Switch settings as follows:
NOTE: Do not duplicate the code of an existing
Control of an installed Ceiling Fan within 100 feet.
Slide the Five Switch Levers in the Wall Control to your
choice of ON (up) or down positions. Use a ball-point
pen or small screwdriver and slide the Levers firmly up
or down.
The Sixth Switch marked ON and I is for dimming
Control of Lights:
Set Switch to ON to allow for
dimming of the lights. Set Switch to I for no dimming of
the Lights.
When the power is restored after installation, push and
hold the Fan OFF Button (
the code in the Receiver.
When the Switch is turned back ON, the Light and Fan
will resume operation as they were prior to the Switch
being turned OFF.
Preset Memory Feature: Your Ceiling Fan/Light
Control is equipped with a preset memory feature.
When the electricity supply to the Fan is switched OFF,
the Control will remember the Light Intensity and Fan
Speed.
9. Wall Control Procedures
) for 3 to 5 seconds to set
Code Switches in the Transmitter may be set in
32 different positions. If your Fan and Light turn ON and
OFF without using your Control, you may be getting
interference from other remote units such as garage
door openers, car alarms or security systems.
To remedy this situations, simply change the Code
Switches in your Transmitter per the instructions of
Section 9.2.
Figure 31
18
WALL CONTROL
CODE SWITCHES
1 - 5
ON
1
2
3
4 5
I
DIMMING
SWITCH
I
CODE
SWITCHES
WALL
CONTROL
ETL Model No.: CF860