Commissioning Via The Control Unit Kp500; Functions Of Keys; Guided Commissioning - BONFIGLIOLI ACTIVE CUBE Guia De Inicio Rapido

Ocultar thumbs Ver también para ACTIVE CUBE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4 Commissioning via the control unit KP500

The optional control unit KP500 enables the parameterization, parameter display and control of the frequency
inverter. It must be connected to the front of the frequency inverter.
Note:
Further methods of commissioning (e.g. via optional communication modules) are described in the operating
instructions manual on the attached CD.
4.1

Functions of keys

Start drive (alternative to control signal S2IND or S3IND). Opening the CTRL menu.
RUN
Opening the motor potentiometer function.
Stop drive (alternative to control signal S2IND or S3IND). Opening the CTRL menu.
STOP
Acknowledging faults
Adjusting the output frequency in the Motor potentiometer function Pot.
▲ ▼
Navigating in the menu structure and selecting parameters.
Increasing/decreasing of parameter values.
Reversal of the direction of rotation independent of the control signal on the terminals Clockwise
S2IND or Anticlockwise S3IND.
ENT
Opening parameters or switching to another menu within the menu structure.
Confirmation of the selected function or the parameter setting.
Aborting parameter settings or switching back to the previous menu within the menu structure.
ESC
Cancelling the function or resetting the parameter value.
Switching over the key function. Access to special functions.
FUN
Changing from Internal reference value int or Motor potentiometer function Pot to the adjusted JOG-
frequency; the drive starts. Releasing the FUN key stops the drive.
4.2

Guided Commissioning

Warning!
The frequency inverter may be connected to power supply every 60 s. More frequent switch-on
operations may damage the device. Consider this for a jog operation of a mains contactor.
Disable the frequency inverter; open contacts at control inputs STOA (digital input S1IND/terminal X210A.3)
and STOB (digital input S7IND/terminal X210B.2).
Switch on mains power.
The frequency inverter carries out a self-test.
Attention!
Before starting the Guided commissioning the machine should not have been in operation because part of the
machine data depends on the operating temperature.
09/08
09/08
Keys
37
37

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido