4.
Make sure that the latching arm is in the unlatched position,
and slide the pass-through module into the bay until it stops.
Figure 2. Installing the Pass-Through Module
5.
Rotate the latching arm upward until it is flush against the
front panel, and the top of the arm is seated in the latch, as
shown in Figure 2, Installing the Pass-Through Module.
2. Attach a Fiber Optic Cable (Optional)
Install a fiber optic cable between the pass-through module and the
target device. Use multimode fiber optic cable, with short-wave lasers,
that adheres to the following specifications:
Fiber Optic Cable
62.5/125 µm (multi-
mode) 200 MHz*km
bandwidth cable
Page 10
Maximum
Minimum
Length
Length
300 meters at
.5 meters
1.0625 Gb/s
150 meters at
2.125 Gb/s
70 meters at
4.25 Gb/s
PT1016 Pass-Through Module Quick Start Guide
Connector
LC