Ir Remote Troubleshooting - Rockford Fosgate RFX Serie Instalación Y Operación

Ocultar thumbs Ver también para RFX Serie:
Tabla de contenido

Publicidad

S
YMPTOM
NO CONN
(Communication Error)
CD Changer does
not operate
Disc is jammed in
the CD Changer
IR R
EMOTE
S
YMPTOM
IR Remote has
poor range
IR Remote does
not work
(LED does not
illuminate)
D
IAGNOSIS
8-pin DIN cable is
disconnected from the
CDX mechanism or
source unit
CDX cable is intermittent
or severely damaged
CDX cable is disconnect-
ed from the Source Unit
or CD Changer
Communication issue
Disc load/unload prob-
lem
T
ROUBLESHOOTING
D
IAGNOSIS
Batteries are weak
Excessive dirt or dust on
IR Remote transmitter
lens
Excessive dirt or dust on
source unit receiver lens
IR remote is outside of
optimum transmitting
range
High sunlight conditions
Batteries are dead
Battery is installed incor-
rectly
Check the connection of 8-pin DIN
cable between the CDX and unit
Check connections and repair or
replace CDX cable as necessary
Check connections at the Source unit
and CD Changer and repair wiring as
necessary
Press Reset on CD Changer
Press Reset on CD Changer. If CD
Changer still does not operate, see
your Local Authorized Rockford
Fosgate Dealer
Check battery condition and replace
as necessary with (1) CR2025 (+3 volt)
battery
Clean transmitter lens with Plexiglas
solution and a non-abrasive cloth as
necessary
Clean receiver lens (compact disc
logo) with Plexiglas solution and a
non-abrasive cloth as necessary
Operate IR remote within about 15 ft
and ±45˚ from horizontal of the
Source unit's faceplate
Operate IR remote closer to Source
Unit
Check battery condition and replace
as necessary with (1) CR2025 (+3 volt)
battery
Check battery installation and repair
as necessary (polarity is indicated on
pc board)
– 46 –
R
EMEDY
R
EMEDY

Publicidad

Tabla de contenido
loading