It is too warm inside the
freezer.
It is too cold inside the freezer.
Water comes out on the floor.
Too much frost and ice are
produced.
The compressor operates
continuously.
The cabinet does not operate
at all. Cooling or interior light
does not operate. No indicator
lamps light.
17
Set a lower temperature.
Make sure that the door is completely closed
and that the insulating strip is complete and
clean.
If warm food products have been put inside
the freezer, wait for a couple of hours and
then check the temperature again.
Distribute the food products to allow cold air
to circulate around them.
Set a warmer temperature.
Action Freeze could have been switched on.
The temperature display shows the highest
temperature inside the cabinet. Thus a
difference between the temperature indicated
on the display and the (average) temperature
measured in another way is normal.
Place the drain hose at the back of the
cabinet above the drain bowl. See the
chapter "Before using the cabinet the first
time".
Make sure that the door is completely closed
and that the insulating strip is complete and
clean.
Set a warmer temperature.
Make sure that the door is completely closed
and that the insulating strip is complete and
clean.
The cabinet is not switched on.
Power does not reach the cabinet. (Try
connecting another electrical device to the
power outlet.)
The power plug is not properly connected.
The fuse has blown.