Initializing the Lifting Column
IMPORTANT:
Before installing the monitor onto the lifting column you must
"Initialize" the column to pre-set it to it's at rest height. Failing to complete this
task may affect the mounting of the cabinet top.
1.
Check that all electrical cable connections are complete, and that all
cable routing is organized, secured and will not interfere with lift
operation. (See pages 7 and 9).
2.
With all electrical cables and connections secure, connect the lifting
column to a power source.
3.
Press and hold the "DOWN" button for a full 5 seconds and observe
the column to ensure the ram jogs up and down slightly. If you do
not hear or see any movement, release the button and repeat this
step until a slight jog movement is observed.
4.
After successfully completing step 2, press the "UP" button on the
up/down switch to extend the lift column to it's full extension.
5.
Press and release the "DOWN" button to fully retract the lift column
to it's at rest height.
UP/DOWN SWITCH