Cooling Fan; Access To Menus - GYS PROGYS 220E FV CEL Manual De Instrucciones

Ocultar thumbs Ver también para PROGYS 220E FV CEL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
5- It is possible to activate / deactivate the remote control without having to physically unplug the remote control. Press the button
seconds, the LED (FIG-2, n°14) indicates the state of the remote control (LED on = remote control on).
Connection
The TIG 300 DC is equipped with a female socket for a remote control.
The specific 7 pin male plug (option ref.045699) enables connection to the different types of manual remote control or foot pedal. For the cabling
layout, please see the diagram below.
REMOTE CONTROL TYPE
Foot pedal
Operating :
• Manual remote control (option ref. 045675)
The remote control enables the variation of current from 50% to 100% of the set intensity. In this configuration, all modes and functions of the
machine are accessible and can be set.
• Pedal (option ref. 045682) :
The pedal control enables variation of current from 10% to 100% of the set intensity.
In TIG LIFT mode, the arc strike, upslope and downslope are not automatic, and are controlled by the User with the foot pedal.

COOLING FAN

To minimise sound and dust aspiration, the station integrates a controlled fan system. The fan's rotation speed depends on the temperature and the
machine's settings.
LOCKING CONTROLS
That feature can lock the knobs and keypad to prevent accidental changes in the settings.
Operation :
Press the button
for 3 seconds, the display shows
No button is enabled, the secondary knob is disabled, the main knob can adjust the value at +/- of the percentage, defined by the «tolerance» setting
(see chapter «Access to menus»).
To unlock the commands, press the
n°12) switches off.

ACCESS TO MENUS

PROGYS 220E FV CEL
Manual remote control
button for 3 seconds, the display shows
Wire description
VCC
Cursor
Common/Earth
Switch
and goes back to current display. The LED (FIG-2, n°12) switches on.
Pin
A
B
C
D
then goes back to current display. The LED (FIG-2,
EN
, for 3
23

Publicidad

Tabla de contenido
loading

Tabla de contenido