Display Introduction
11
12
1. Date and time
2. Clock icon: appears when the timing function is used.
Note: this function is only avaliable for a-AB41PH model.
3. Computer icon: appears when connects to a computer.
4. Endpoint mode
5. Measurement icon: blinks when measurement is in progress.
6. Pinter icon: touch to print.
7. Calibration icon: touch to calibrate; blinks when calibration is in progress.
8. Menu icon: touch to enter menu settings.
9. Beaker icon: touch to recall measurement data.
10. User ID icon: touch and then press
11. Temperature: touch to switch between MTC and ATC temperature.
Touch the Menu icon
to enter the following setup menu:
12. Setup: touch to enter parameter setup menu.
13. i-Steward: touch to enter sensor condition menu.
14. Settings: touch to enter meter's setup menu.
Note: when you enter the three menus introduced above, touch the related sub-menu items to finish
settings. Please refer to the first page of the flyer for detailed information about some of the sub-
menu items.
Install the stand-alone electrode holder
1.
Attach the magnetic part on the bottom
of the meter to the magnetic part on the stand-
alone electrode holder to finish installation.
(Both marked in red demonstrated below.)
Version B ©Ohaus Corporation 2021 All rights reserved
1
2
3
4
5
6
10
13
or
button to select user by user ID.
2.
by turning clockwise to tighten or turning
counterclockwise to loosen. When they are
loosened, you can move the holder up and
down, forward and backward to the desired
angle. Then you can tighten the knobs to fix
the holder.
Loosen
7
8
9
14
The two tension knobs can be adjusted
Tighten
Loosen
Tighten
15
16
Buttons:
15. Up button:
a. When setting parameters, increases the setting
value or displays the previous option.
b. When in setup menu, press to scroll up to the
previous page of menu selections.
c. When in calibration and PH ECS process, press to
repeat the previous step.
16. Home button:
a. Press to turn on the meter.
b. Press to start a new measurement.
c. Press to exist from the current mode or menu and
return to the measurement mode.
17. Down button:
a. when setting parameters, decreases the setting
value or displays the next option.
b. when in setup menu, press to scroll down to the
next page of menu selections.
c. When in calibration and PH ECS process, press to
move to the next step.
Note: the stand-alone holder boasts a harness
storage design. You can push the electrode's
cable in the slots marked in red below, roll up
and fix the harness storage strip located at
the bottom of the holder, and pass the cable
through the strip.
Scan the QR code to get a-AB33PH
and a-AB41PHs' instruction manual.
17